Product
Profile
MDM3100 is a powerful multifunction power meter that measures more than 60 parameters such as P, Q, cosΦ, F, kWh, kvarh, etc.
The standard MDM3100 has RS-485 communication protocol, 2 energy pulse outputs (active and reactive each) functions.
With optional modules, MDM3100 can perform more functions: harmonic analysis, 8 digital signal inputs, 4 programmable relay outputs, 4 programmable analog outputs (0-5V or 4-20mA), data storage, Profibus communication, Ethernet networking capabilities.
MDM3100 fulfills all the important
requirement of IEC 60668;IEC61557-12; IEC6
EMC
and other safety standard
IEC61326-1
IEC6
IEC6
IEC61010-1
Functions
Description
Item |
Description |
||
Main unit |
Real-time
measurement |
Phase Voltage |
Phase Voltage, average phase Voltage |
Line
Voltage |
Line
Voltage, average line Voltage |
||
Current
|
Phase
Current, average phase Current, zero sequence Current |
||
Active
Power |
Phase
active Power, 3 phase active total Power |
||
Reactive
Power |
Phase
reactive Power, 3 phase reactive total Power |
||
Apparent
Power |
Phase
apparent Power, 3 phase apparent total Power |
||
Power
4 quadrant |
Power
4 quadrant |
||
Frequency |
System
frequency |
||
Power
Factor |
Phase
Power factor, 3 phase total Power factor |
||
Demand
statistic |
Demand |
3
phase active/reactive demand Power, demand apparent Power |
|
Energy
Reading |
Active
energy |
Imported,
exported and net active energy, 1 channel active energy pulse output |
|
Reactive
energy |
Imported,
exported and net reactive energy, 1 channel reactive energy pulse output |
||
Multi
tariff billing |
Multi
tariff setup |
||
Time
display |
Real
time display |
Year/month/day/hour/minute/second |
|
Data
communication |
RS-485
communication |
1
Modbus-RTU protocol |
|
Optional Module |
Remote
signal input module |
8
channels |
Status
detection, SOE event record |
Relay
output module |
4 channels
programmable overlimit/underlimit alarm |
Programmable
over/under limit value for real time measurement, Volt- age/Current
unbalanced ratio, demand value, harmonics, remote signal. The overlimit /underlimit command can be read
thru com. Port. |
|
Analog
output module |
4
channels programmable |
4-20mA
or 0-5V |
|
Data
storage module |
Storage
capacity:2GB |
Store
real time measured value in cycle, Voltage/Current unbalanced ratio, demand
value, harmonics, and remote signal. |
|
Harmonic
analysis module |
Total
harmonic distortion for Voltage/Current |
3
phase, single phase, neutral line |
|
Even/odd
harmonic distortion |
Harmonic
distortion (2nd to 63rd) |
||
Fundermental
Voltage / Current |
Magnitude,phase angle |
||
Fundermental
active/reactive power |
Magnitude
Phase angle |
||
Harmonics,
individual |
|
||
Current K
factor |
|
||
Profibus
communication module |
1channel |
Profibus-DP protocol |
|
Ethernet
networking communication module |
1channel |
|
|
TCP/IP
protocol |
Measurement
Accuracy
Parameters |
Display |
Direction |
Accuracy |
Voltage |
0~9999kV |
|
Class0.2 |
Current |
0~9999kA |
|
Class0.2 |
Power factor |
-1~+1 |
Directional |
Class 1 |
Frequency |
45~65Hz |
|
0.01Hz |
Active Power |
-9999~9999Mw |
Directional |
Class0.5 |
Reactive Power |
-9999~9999MVAr |
Directional |
Class0.5 |
Apparent Power |
0~9999MVA |
|
Class0.5 |
Active Demand |
-9999~9999MW |
|
Class 1 |
Reactive Demand |
-9999~9999MVAr |
|
Class 1 |
Active Energy |
0~9999999.99MWh |
Directional |
Class 1 |
Reactive Energy |
0~9999999.99MVArh |
Directional |
Class 2 |
Phase Angle |
0.0°~359.9° |
Directional |
Class 2 |
Current total
harmonic % |
0~100% |
|
Class 2 |
Voltage total harmonic % |
0~100% |
|
Class 2 |
Technical
Specification
Current Input |
|||||
Input Current:0~ Measurement scope:0.5%~120%In Overload capacity:2 X rated
continuously, Power consumption:≤0.2VA per phase |
|||||
Voltage Input |
|||||
Input Voltage:0~400VAC
(L-N),0~693VAC(L-L)(Voltage
value can be set up) System frequency:45~65Hz Measurement scope:3%~120%Un Overload Capacity:2 X rated
continuous, 2500V/1s non continuous Power consumption:≤0.5VA per phase |
|||||
Switch Status (optional) |
|||||
Input Channels: Input Type: Isolated Voltage:
|
8 channels Dry contact 2500VAC |
||||
Relay Output (optional) |
|||||
Output Channels |
4 channels
programmable |
||||
Output Type |
Mechanic contact, constant on output |
||||
Contact Capacity |
|
||||
Analog Output (optional) |
|||||
No. of outputs |
4 channels
programmable |
||||
Output signal |
4~20mA
or 0~5V |
||||
Response time |
≤400ms |
||||
Pulse Output (standard) |
|||||
No. of outputs |
2 channels(active/reactive energy each) |
||||
Serial com. Port (standard) |
|||||
No. of outputs |
1 RS-485 port |
||||
Communication
protocol |
Modbus-RTU protocol |
||||
Baud rate |
2400、4800、9600、19200、38400
bps |
||||
Profibus com. Module (optional) |
|||||
No. of Channels |
1channel |
||||
Communication protocol |
Profibus-DP
protocol |
||||
Ethernet networking Module
(optional) |
|||||
No. of outputs |
1 channel |
||||
Communication protocol |
TCP/IP protocol |
||||
Other parameters |
|
Auxiliary
Power |
85~265VAC/DC |
Display
module |
LCD
display luminosity can be adjusted
|
Temp.
drifting factor Withstand
Voltage(input against output ) Total
power consumption Operation
temperature Storage
temperature Operation
humidity Pollution
Class Material
of housing |
<100PPM/℃ 2500V/1min <8VA 5~95%RH 2 Class Flammability acc. To UL94V0 |
Main
unit |
96 x 96 x |
Dimensional
Size: Main unit+ module |
96 x 96 x |
Installation
Size: |
91